1-0100-600-0004-00
ESSER TWIN 700
 DOUBLE WALL HARDENED
 BALL JOINT

Ball joints are used to compensate for slight differences in height. These can have topographical or thermal causes. Thermal influences in particular are dynamic. Ball joints form a relief point here and prevent emerging stresses in the pipeline.
If a pipeline has to be opened at a certain point for inspection purposes, ball joints allow it to be swung out so that access to the inside of the line is free.

Sub CategoryDOUBLE WALL HARDENED
SERIESESSER TWIN 700
NOMINAL DIAMETER 100
END STYLE (Outlet-Norm) EN1092-1/32/A/DN100/PN10 EN1092-1/02/DN100/PN10
END STYLE (Inlet) Fixed flange (EN1092, Shape A, PN10)
END STYLE (Outlet) Weld-end/Loose flange (EN1092, Shape A, PN10)
WALL THICKNESS [MM] 7.7
WORKING / TEST PRESSURE [BAR] 20
Inner Wall 4.5
Outer Walll 3.2
NORMAL PRESSURE BAR 10
Weight 35.5
HARDNESS [HRC] 63
Notes Other dimensions and end styles by request.